Power Control & Protecti...
Meter and Measuring Inst...
Industrial Switchgear Se...
Conduit & Connector Series![]() |
The electromagenetic starters HT3 Dxx series are devices designed for remote control,direct control and protection of induction motors coiled and operating according to a starter scheme"star/delta" .They are a combination of three contactors HT1 Dxx series,time relay and a set of buttons "start" and "stop" fabric cabled.They provide the easy motor unwinding giving possibility for setting the time for unwinding in "star" as the time for switching between "star" and "delta" is fixed to 0.5 seconds.
|
| Functions | |
|
¡ö switching on/off alternating current three phase motors operating according to a scheme"star-delta"
| |
| Technical Data | |
|
* Rated voltage of the controlling voltage:400VAC,50/60 Hz Note:In case you need different controlling coils voltage of the starers you can turn to our regional representatives. * Rated operating voltage:690V * Rated operating current range:from 7 to 93A AC * Insulation voltage:>690V * Surge voltage wear resistance: ¡Ý 6000v * Joining terminal :screw terminal * Little power consumprion and small dimensions * Connecting: - flexible or rigid conductors with or without cable terminal for joining to the consumer and section according to the motor power - three by three inlets/outlets supplied with orifices for the cables * Possibility for operation at higher frequency * Mounting: - mounting to a flat surface(wall) with bolts/screws - mounting position:vertical gradient-maximum ¡À5¡ã * Plastic:wear resistance of UVrays and non-flammable(self-extinguishing material) * The metal body is covered with corrosion-proof paint Ambient temperature: -10¡æ+60 ¡æ * Altitude:up to 2000m | |
![]() |
|
|
| |||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||
|
Note:It is necessary that thermal protection with suitable range is mounted to protect the controlled motor.The shown values of magnetic starters are for normal regimes for motor control,for hard operation regimes are chosen starters which correspond to the current rating of the motor
| ||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||
|
Note:It is necessary that thermal protection with suitable range is mounted to protect the controlled motor.The shown values of magnetic starters are for normal regimes for motor control.for hard operation regimes are chose starters which correspond to the current rating of the motor | ||||||||||||||||||||||||||||||||||||||||||||||